Product parameter |
Project |
Parameter |
OFF indicates the maximum voltage |
2.0 V |
Maximum leakage current |
1 mA |
Maximum capacitive load |
1μF |
Maximum cable length |
20 m |
Shell protection |
IP65 |
Operating ambient temperature |
-10 ºC +50 °C( Freeze-free) |
Storage ambient temperature |
-25 ºC +60 °C( Freeze-free) |
Operating relative humidity |
35 85 % Rh(non-condensing) |
Storage relative humidity |
35 95 % RH |
Bient light selfburning lamp |
1500 lx or below |
Vibration |
10 ~ 55 Hz, 0.7mm compound amplitude, 20 frequency sweeps in X, Y and Z directions |
Impact |
100 m/s (about 10 G) 16 ms pulses, 1000 in each axis in the X, Y and Z directions |
Material |
Main device (internal support pressed wrong aluminum, stainless steel shell) |
Mask PC |
Project |
Parameter |
Minimum measured object |
Diameter 30, 40, 50, 70, 150 mm (depending on setting) |
Detectable Angle |
270(° -45° 225°) |
Response time (ON to OFF) |
Default: 120ms(40 ms to 400 ms) |
Recovery time (OFF to ON) |
Default: 120ms(40 ms to 400 ms) |
Standard scan period |
40ms |
Maximum monitoring area |
50m(standard white reflective panel) |
Maximum detection distance(According to test specimen size) |
4m (40mm specimen) 8m(80mm specimen) 12m(120mm specimen) |
Type of light source |
905nm infrared laser |
Laser classification |
1 type IEC / EN 60825-1: 2014 |
Rated supply voltage |
24 V DC ±10 % |
Power consumption |
Max. 10W (excluding load) |
Output mode |
Two-way PNP or NPN (can be set according to the software) |
Maximum load curren |
t 100 mA |
Residual voltage (ON period) |
Max 2.5V |