Certification: | CE |
---|---|
Safety Standard: | ISO13849-1 |
Safety Level: | Level 3/Cat.4 |
Samples: |
---|
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Switch Safety level | |
Standard | EN60947-5-1/GB/T14048.5 |
Security classification | Dual-channel interlocking is suitable for class 3 or Class 4 systems |
B10D | 1 million times |
Certification | CE CCC(CQC) |
Mechanical life | More than 1 million |
Electrical life | More than 1 million |
Electrical characteristics | |
Rated insulation voltage (Ui) | Rated insulation voltage (Ui)300V |
Protection level against electric shock | Class II (double insulation) |
Pollution degree (operating environment) | 3(EN60947-5-1) |
Pulse voltage withstand (EN60947-5-1) | 2.5KV |
Contact resistance | Below 25mΩ |
Insulation resistance | Below 100mΩ |
Rated open heating current (lth) | 10A |
Conditional short-circuit current | 100A |
Contact spacing | 2.5mm |
Operating characteristics | |
Minimum power | 15N |
Maximum execution speed | 160mm/s |
Maximum execution frequency | 2 cycles per second |
Minimum switching current at a specified voltage | 5mA@5VDC |
Contact type | |
Safety contact | 2-way NC 1- way NC |
Auxiliary contact | 1 way NO |
Type of use | |
Load class | AC-15 DC-13 |
Rated operating voltage (Ue) | 230V 24V |
Rated operating current (Le) | 4A |
Environment | |
Housing protection class | Ip67 |
Operating temperature | -20~+80ºC |
Use environment | Below 95% |
Vibration resistance | 10-55Hzunilateralamplitude 0.75mm |
Stamping resistance | 300m/s2 |
Material | |
weight | About 200g |
Shell material | The thermoplastic is UL certified |
Execution materials | SUS304 |
Suppliers with verified business licenses