Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Contact: | 2C1O.3C.1C1O.2C |
| Safety Standard: | EN 60947-5-1 |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Technical Parameter | ||
| Safety Level | ||
| Standard | EN60947-5-1,GB14048.5 | |
| Certification | CE,UL508 | |
| Mechanical Durability | 100W operations min. | |
| Electrical Durability | 50W operations min. (100mA resistive load) | |
| Environment | ||
| Degree of protection | Ip67 | |
| Ambient operating temperature | −20 to 55°C (with no icing) | |
| Ambient operating humidity | 95% max. | |
| Electrical Characteristics | ||
| Rated insulation voltage (Ui) | 300V | |
| Protection against electric shock | Class II | |
| Pollution degree (operating environment) | 3 (EN60947-5-1 | |
| Impulse withstand voltage(EN60947-5-1) | 2.5KV | |
| Contact resistance | 25 mΩ max. | |
| Insulation resistance | 100 MΩ min. | |
| Conventional free air thermal current (Ith) | 10A | |
| Conditional short-circuit current | 100A | |
| Contact gap | 2.5mm | |
| Utilization Category | ||
| Load Category | AC-15 | DC-13 |
| Rated operating voltage (Ue) | 240V | 24V |
| Rated operating current (Ie) | 3A | 2A |
| Working Chracteristics | ||
| Direct opening force (min) | 60N | |
| Holding force (Fzh) | 1300N | |
| Operating speed | 0.05~0.5m/s | |
| Operating frequency | 30 operations/minute max. | |
| Minimum switching current under |
10mA@5VDC | |
| Material | ||
| Weight | 400g | |
| colour | Dark Yellow + Black | |
| Shell material | UL certified glass filled PBT | |
| Actuator material | SUS304 | |
| Others | ||
| ated operating voltage of solenoid | 0.2A@24VDC±10 | |
| olenoid rated power | 4.6W | |
| olenoid DC resistance | 125 Ω±10% | |
| ated operating voltage of indicator lamp | 1mA@24VDC | |