Customization: | Available |
---|
Still deciding? Get samples of US$ 2/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Accessory selection table | ||
Model | Product working characteristics | Order no. |
TMLE-K1R | Prevent mis-closing flexible actuator | LOT555242R1 |
TMLE-K2R | Prevent mis-closing horizontal actuator | LOT623508R2 |
TMLE-K3R | Prevent mis-closing vertical actuator | LOT433508R3 |
TRL1-F03 | Manual release key | LOTTRL1F03 |
TRL1-H03 | Back release accessory | LOTTRL1H03 |
Model | Product working characteristics | Order no. |
TMLE-K1 | Flexible actuator | LOT555242K1 |
TMLE-K2 | 180° horizontal actuator | LOT623508K2 |
TMLE-K3 | 90° vertical actuator | LOT433508K3 |
WJ-16015 | M16 x 1.5 nylon waterproof connector | LOTWJ16015 |
TMLE safety interlocking device series technical parameter | ||
Environment | ||
Protection level against electric shock | (Safe supply voltage SELV) | |
Operating environment (pollution level) | 3 | |
Protection grade | IP67 | |
Operating temperature | -20...+55ºC | |
Relative humidity | 5...95% | |
Mechanical parameters | ||
Mechanical life | More than 500,000 times | |
Flexible key insertion deviation | Max.:±2mm | |
Minimum operating force | 15N | |
Locking retainer Fzh (ISO14119) | 1700N | |
Radius of the revolving door | Min.:≥250mm | |
Impact resistance | 2 300m/s |
|
Resistance to vibration | 10~55Hz unilateral amplitude 1mm | |
LOCK Lock control signal | ||
Working current | 3mA | |
LOCK Signal high level voltage | >10V | |
LOCK Signal low voltage | <5V | |
Other | ||
Body weight | About 240g | |
Material | Nylon/stainless steel | |
Safety level | ||
Standard | EN60947-5-1 GB/T14048.5 | |
Certification | CQC / FCC | |
Output | ||
Output type (working well) | 3NC,2NC/1NO,2NC,1NC/1NO | |
Output voltage | DC 24V | |
Load current | Max.:100mA | |
Conduction pressure drop | Max.:0.3V | |
Turn off the leakage current | 30μA | |
Capacitive load | Max.:100μF | |
Electrical parameters | ||
Working voltage | DC 24V(+10%~-15%) | |
Rated power | 5.3W(No load) | |
Operating frequency | 3Hz | |
Door opening delay | 50ms | |
Door locking delay | 200ms | |
Start-up time | 1s | |
TMLE safety interlocking device series Interface description | ||
S/N | Signal name | Instructions |
1 | 3A | Output3 |
2 | 2B | Output2 |
3 | 2A | |
4 | 1B | Output1 |
5 | 1A | |
S/N | Signal name | Instructions |
6 | 3B | Output3 |
7 | L+ | Lock control signal input, connect high level or power supply |
8 | L- | Lock control signal input, connect low level or ground |
9 | A1 | Power input,+24V |
10 | A2 | 0V |