Customization: | Available |
---|---|
Warranty: | 18 Months |
Application: | Industrial Security Area |
Still deciding? Get samples of US$ 115/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical parameter | ||
Security level | ||
Standards | IS0 13849-1 IEC/EN60947-5-3 | |
Safety classification | ISO 13849-1 compliant class 4 switch/SIL3 dual channel interlock for PLe/PLd | |
Certificate | CE CQC | |
Protection | ||
Safety short-circuit Overheat protection stops protection and restarts Current limit Reverse polarity protection Overload protection Transient noise protection Over Voltage Protection Failure pulse protection |
||
Output | ||
Security output | 2 way Redundant PNP or NPN output (Self diagnostic test pulse) |
|
AUX output | 1 way PNP or NPN output(door close / door lock / auxiliary output fault indication) |
|
Technical parameters | ||
Deviation of bolt insertion | Max.:±2mm | |
Lock hold force Fmax(IS014119) | 9750N or 3000N | |
Lock hold force Fzh(IS014119) | 77500N or 2000N | |
Minimum operating radius of revolving door | ≥220mm | |
Output current | DC 24V±15% | |
Rated power | 4.6W(no load) | |
Output current | Max.:200mA | |
Output conduction voltage drop | <2.5V@200mA | |
Leakage current | <100uA | |
Operating Frequency | 0.5Hz | |
Response time | 100ms(Independent work) | |
Risk time | 100ms | |
Start-up time | 3.5s | |
Protection level | IP67 | |
Operating temperature | 0...+55ºC | |
Relative humidity | 5...95% | |
Materials | Nylon/Zinc alloy/Stainless steel | |
PFHd | <4.2x10 -8 | |
MTTFd | 288 years |