• External relay contact Monitoring (EDM) function safety light curtains
  • External relay contact Monitoring (EDM) function safety light curtains
  • External relay contact Monitoring (EDM) function safety light curtains
  • External relay contact Monitoring (EDM) function safety light curtains
  • External relay contact Monitoring (EDM) function safety light curtains
  • External relay contact Monitoring (EDM) function safety light curtains

External relay contact Monitoring (EDM) function safety light curtains

Safety Standard: ISO13849-1 /IEC61496-1/2(Type 4)
Safety Level: PLe Cat.4 SIL3
Detection Height: 0.1-6M
Samples:
US$ 800/Set 1 Set(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
External relay contact Monitoring (EDM) function safety light curtains pictures & photos
External relay contact Monitoring (EDM) function safety light curtains
US $150-800 / Set
Min. Order: 1 Set
Diamond Member Since 2023

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory

Basic Info.

Model NO.
SLC-AD
Optical axis spacing
7.5/15/30mm
Resolution
14/25/40mm
Contect Type
Air Plug /Line
Voltage
24VDC±15%
Output
2NPN/NPN Redundant output
Output Type
NPN/PNP
Anti-interference
>10000Lux
Optical eyes
4-319
Current
>150mA
Synchronous
light /Line
Transport Package
Paper Box
Trademark
SLC
Origin
China

Product Description

Performance characteristics
 
SLC-AD safety light grid is designed with the most advanced international functional safety concepts and technologies to provide customers with a safe workplace, with the following advantages:
 
  • TYPE4 security level
SLC-AD complies with ISO13849-1, Cat.4 category, and reaches PLe safety level; Complies with IEC/EN62061 and IEC/EN61508SIL3 safety levels;
Complies with Type4 safety based on EN/IEC61496-1/-2 and GB/T19436-1/-2.

 
  • No blind zone design
Suitable for structurally constrained applications,it's easy to build comprehensive blind zone protection area when applying multiple L or U-shaped combinations.
 
  • Multiple sets of cascades
Three sets of light curtains cascade combinations can be realized. The cascade combination effectively prevents mutual optical interference between multiple sets of light curtains
 
  • Optical/line synchronization optional design
SLC-AD can realize optical or line synchronization optionally, and different synchronization methods can be selected according to the field situation.
 
  • Redundant OSSD output with self-diagnostics
Dual independent redundant outputs are used,drive safety relays or safety PLC to improve the safety performance of the system
 
  • Multiple optional setting functions
SLC-AD safety light curtain can be easily configured with functions such as interlock reset, external EDM, bypass and override, and fixed shielding and floating shielding through PC software, and qualified user operators can easily configure functions according to site usage.
 

External relay contact monitoring (EDM) function

The "External Relay Contact Status" is monitored to prevent the loss of safety protection functions due to external relay adhesion failures.
 

Interlock and reset function

The light curtains has optional interlock and reset functions, which can be easily implemented for manual reset and automatic reset.
 

Bypass and override functions

It is convenient to shield light grids for short periods of time under specific conditions without affecting machine operation.
 

Fixed and floating shielding

Fixed shielding facilitates special areas with shielding. Floating shielding is convenient for small and large workpieces and can also be used in scenarios where workpieces continue to pass.
External relay contact Monitoring (EDM) function safety light curtainsExternal relay contact Monitoring (EDM) function safety light curtainsExternal relay contact Monitoring (EDM) function safety light curtainsExternal relay contact Monitoring (EDM) function safety light curtains
 
Technical parameters
System parameters
Project Parameter
 
Safety standards
IEC61496-1,EN61496-1, GB/T19436-1(Type4 ESPE); IEC61496-2, EN61496-2, GB/T19436-2(Type4 AOPD); ISO13849-1 ( PLe,Cat.4);
IEC62061, EN62061(SIL3) IEC61508, EN61508 (SIL3)
PHFd 3.17×10-8
MTTFd 312 years
Power protection Power supply reverse/short circuit ground protection
Input/output protection All inputs/outputs are shorted to power or ground protection
Optical axis spacing 7.5mm/15mm/30mm
Resolution 14mm/25mm/40mm
Synchronization mode Optical/wire synchronization (optional depending on wiring method)
System startup time 5s
Response time Reference selection table
Aperture degree (EAA) ±2.5º
Protection length 0.1~6m
Protection degree IP65
Anti-interference >10,000lx ambient illumination
Temperature Working temperature -10~55°C (no freezing)
Humidity Maximum relative humidity 95% (no condensation)
Storage Storage temperature -20-85°C, maximum relative humidity 95%
Vibration resistance 10-55HZ amplitude 0.7mm
Impact resistance 10g 16ms 1000 times in the x.y ,z direction
Emission parameters
Project Parameter
Supply voltage 24V±15%
Supply current Max 150mA
Emit LED waves Infrared LED (peak wave 940nm)
Receive parameters
Project Parameter
Supply voltage 24V±15%
Supply current Max 150mA (excluding OSSD1 and OSSD2 load currents)
OSSD1 or OSSD2 Output type 2 NPN or 2 PNP
OSSD1or OSSD2Max load current 500mA
OSSD1or OSSD2Output residual voltage >3V
OSSD1or OSSD2 Leakage current Max 0.1mA
OSSD1or OSSD2Max capacitive load 0.1μF
Load connection resistance Max 2.5Ω
EDM input Low level 0-3V, high level 10-30V
Reset input Low level 0-3V, high level 10-30V
 

Product application cases
External relay contact Monitoring (EDM) function safety light curtainsExternal relay contact Monitoring (EDM) function safety light curtainsExternal relay contact Monitoring (EDM) function safety light curtains
Factory show
External relay contact Monitoring (EDM) function safety light curtainsProducts certification

External relay contact Monitoring (EDM) function safety light curtains
 Our Exhibition
External relay contact Monitoring (EDM) function safety light curtains
Company Cooperative units
External relay contact Monitoring (EDM) function safety light curtains


Q: Can i get some samples ?/Do you offer samples available?
A: Yes, we can provide sample, but the cost of the sample is paid by the customer, if you feel satisfied and have the next mass production order, we can deduct the cost of the sample.

Q: How is the warranty?
A:our warranty time is 18 months. If the product has quality problem within 18 months, please return it to us, we will repair it; if we can't repair it successfully, we will give you a new one; but the man-made damage, improper operation and force majeure will be excepted. And you will pay the shipping cost of returning to us, we will pay the shipping cost to you.

Q:How about the quality of the products?
A:we have the certification of CE,CCC,CQC,EU,TUV,UL, and products Safety Level archived Ple,SIL,Type 4,Cat.4 etc.

Q: What is the quality guarantee?
A: We are an ISO 9001-2015 ,ISO 14001 -2015 certified manufacturer, we have strict quality control system. Besides calibration, each set product we also do aging test before shipment, so the quality is guaranteed.

Q: Do you have any products in stock?
A: Depend on the order quantity.

Q: Can I be your distributor?
A: Yes, we are looking for distributors in oversea market.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.