| Safety Ratinds | |
| Standards | ISO 13849-1 |
| Satety Classification | Cat. 4 Per ISO 13849-1 |
| Power | |
| Power Supply | 24V /DC |
| Power Consumption | 2W |
| Input | |
| Safety Input | 1 ch. or 2 ch.N.C. or Safety light curtain |
| synchronize | Infinite (ch2 before ch1) with Auto Reset |
| Max. input resister | 110W |
| Reset | Automatic/manual Reset |
| Power-up delay/ recover time | 1s/100ms |
| Response time | 15ms |
| OUTPUT | |
| Safety output | 3 ch. N.O. |
| Auxiliary output | 1 ch. N.C. |
| Rated Impulse withstand Voltage | 2500V |
| Switching Current @Voltage,Min. |
10mA/10V |
| Fuses,Output | External 6 A slow blow or 10 A fast acting |
| Electrical Life | 1×105(1NO:3A 24VDC,Resistive load,1s on/9s off ) 1×105(1NO:6A 250VAC,Resistive load,1s on/9s off) |
| Mechanical life | 2,000,000 times |
| Environmental and Physical Characteristics | |
| Enclosure Type Rating /Terminal Protection |
IP40/IP20 |
| Operating temp. (ºC) | -5…+55ºC |
| Vibrator | 10…55Hz,0.35mm |
| Shock | 10g,16ms,100 shocks |
| Mounting | 35mmDIN rail |
| Weight (g) | 150 |
| Conductor Size, Max | 0.2…4mm2 |